sample_signal_device_impl
sata
Simics Reference Manual
/
5 Classes
/
sample_timer_device
Description
This is the
sample_timer_device
class, an example of how timer devices can be written in Simics.
Interfaces Implemented
conf_object, log_object
Notifiers
cell-change
Notifier that is triggered after the object's cell was changed.
object-delete
Notifier that is triggered just before Simics object is deleted.
queue-change
Notifier that is triggered after the object's clock was changed. New clock can be obtained with the SIM_object_clock function.
Port Objects
bank.regs
sample_timer_device.regs
Commands for this class
info
– print information about the object
status
– print status of the object
Attributes
irq_dev
Optional
attribute;
read/write
access; type:
o|[os]|n
Device an interrupt should be forwarded to (interrupt controller)
Required interfaces:
signal
.
Provided By
sample-timer-device
sample_timer_device.regs
Interfaces Implemented
conf_object, log_object, bank_instrumentation_subscribe, instrumentation_order, int_register, io_memory, register_view
Notifiers
cell-change
Notifier that is triggered after the object's cell was changed.
object-delete
Notifier that is triggered just before Simics object is deleted.
queue-change
Notifier that is triggered after the object's clock was changed. New clock can be obtained with the SIM_object_clock function.
Commands for interface bank_instrumentation_subscribe
bp-break-bank
– set device access break
bp-run-until-bank
– run until specified device access occurs
bp-trace-bank
– enable tracing of device accesses
bp-wait-for-bank
– wait for specified device access
Commands for interface instrumentation_order
instrumentation-move
– reorder instrumentation connections
instrumentation-order
– list instrumentation order for object
sample_signal_device_impl